Product Status | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 | Power (Watts) | Applications | Voltage - Isolation | Efficiency | Operating Temperature | Features | Mounting Type | Size / Dimension | Approval Agency | Standard Number |
|
|
|
MBC75 (75W) |
Box |
Obsolete | Open Frame | 1 | 85 ~ 264 VAC | 12V | - | - | - | - | - | 6.25 A | - | - | - | - | - | 75W | Medical | 4 kV | 90% | -40°C ~ 70°C (With Derating) | Adjustable Output, DC Input Capable, PFC, Universal Input | Chassis Mount | 3.00" L x 2.00" W x 1.00" H (76.2mm x 50.8mm x 25.4mm) | CE | - |
|
|
|
LCW320 (320W) |
Box |
Active | Enclosed | 1 | 85 ~ 305 VAC, 120 ~ 430 VDC | 12V | - | - | - | - | - | 26.7 A | - | - | - | - | - | 320W | ITE (Commercial), Industrial | 4 kV | 86% | -30°C ~ 70°C (With Derating) | Adjustable Output, DC Input Capable, PFC | Chassis Mount | 8.47" L x 4.53" W x 1.18" H (215.0mm x 115.0mm x 30.0mm) | CE, EN, UKCA, UL | 62368-1 |
|
|
|
PSC-160 (160W) |
Box |
Active | Enclosed | 2 | 90 ~ 264 VAC, 127 ~ 370 VDC | 27.6V | 27.6V | - | - | - | - | 3.8 A | 2 A | - | - | - | - | 160W | ITE (Commercial) | 3 kV | 90% | -20°C ~ 70°C (With Derating) | Adjustable Output, PFC, Universal Input | Chassis Mount | 6.12" L x 3.35" W x 1.46" H (155.4mm x 85.0mm x 37.0mm) | CB, CE, cURus, TUV | - |
|
|
|
HEP-150 (150W) |
Box |
Active | Enclosed | 1 | 90 ~ 305 VAC, 127 ~ 431 VDC | 54V | - | - | - | - | - | 2.8 A | - | - | - | - | - | 151W | ITE (Commercial) | 3.75 kV | 94% | -55°C ~ 70°C (With Derating) | Adjustable Output, IP65, PFC | Chassis Mount | 8.98" L x 2.68" W x 1.53" H (228.0mm x 68.0mm x 38.8mm) | CB, CE, cURus | - |
|
|
|
VOF-180 (180W) |
Box |
Active | Open Frame | 1 | 80 ~ 264 VAC | 48V | - | - | - | - | - | 2.5 A | - | - | - | - | - | 120W (180W Forced Air) | ITE (Commercial) | 3 kV | 92% | -40°C ~ 70°C (With Derating) | Adjustable Output, Standby Output, Universal Input | Chassis Mount | 4.00" L x 2.00" W x 0.75" H (101.6mm x 50.8mm x 19.1mm) | CB Scheme, EN, FCC, IEC, SIQ, TUV, UL | 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3 |
|
|
|
SE-600 (600W) |
Box |
Not For New Designs | Enclosed | 1 | 90 ~ 132 VAC, 180 ~ 264 VAC, 254 ~ 370 VDC | 15V | - | - | - | - | - | 40 A | - | - | - | - | - | 600W | ITE (Commercial) | 3 kV | 84% | -20°C ~ 60°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 9.72" L x 5.00" W x 2.50" H (247.0mm x 127.0mm x 63.5mm) | cURus | - |
|
|
|
VMS-180 (180W) |
Tray |
Active | Open Frame | 1 | 80 ~ 264 VAC | 24V | - | - | - | - | - | 5 A | - | - | - | - | - | 120W (180W Forced Air) | Medical | 4.2 kV | 90% | -40°C ~ 70°C (With Derating) | Adjustable Output, Standby Output, Universal Input | Chassis Mount | 4.00" L x 2.00" W x 0.75" H (101.6mm x 50.8mm x 19.1mm) | CB Scheme, EN, FCC, IEC, TUV, UL | 55011 Class B; 60601-1; 61000-3-2; 61000-3-3 |
|
|
|
VOF-180 (180W) |
Box |
Active | Open Frame | 1 | 80 ~ 264 VAC | 24V | - | - | - | - | - | 5 A | - | - | - | - | - | 120W (180W Forced Air) | ITE (Commercial) | 3 kV | 90% | -40°C ~ 70°C (With Derating) | Adjustable Output, Standby Output, Universal Input | Chassis Mount | 4.00" L x 2.00" W x 0.75" H (101.6mm x 50.8mm x 19.1mm) | CB Scheme, EN, FCC, IEC, SIQ, TUV, UL | 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3 |
|
|
|
PMR (300W) |
Bulk |
Active | Enclosed, Conformal Coated | 1 | 88 ~ 264 VAC | 5V | - | - | - | - | - | 60 A | - | - | - | - | - | 320W | ITE (Commercial) | 3 kV | 84% | -10°C ~ 70°C (With Derating) | Adjustable Output, PFC, Universal Input | Chassis Mount | 8.46" L x 4.53" W x 1.18" H (215.0mm x 115.0mm x 30.0mm) | CB, CE, CCC, cURus, TUV | - |
|
|
|
MPQ-200 (200W) |
Box |
Active | Open Frame | 4 | 90 ~ 264 VAC, 127 ~ 370 VDC | 5V | 12V | -5V | -12V | - | - | 12 A | 5.3 A | 1 A | 1 A | - | - | 141W (133W Forced Air) | Medical | 4 kV | 78% | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote On/Off, Remote Sense, Universal Input | Chassis Mount | 7.00" L x 4.22" W x 1.40" H (177.8mm x 107.2mm x 35.6mm) | CB, CE, cURus, TUV | - |
|
|
|
WLP350 (350W) |
Bulk |
Active | Open Frame | 1 | 90 ~ 264 VAC, 390VDC | 15V | - | - | - | - | - | 12 A | - | - | - | - | - | 180W (325W Forced Air) | ITE (Commercial) | 3 kV | 92% | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Standby Output, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.00" H (127.0mm x 76.2mm x 25.4mm) | CB, CCC, CE, cUL, NEMKO, UL | 62368-1 |
|
|
|
RPS-400 (400W) |
Box |
Active | Enclosed | 1 | 80 ~ 264 VAC, 113 ~ 370 VDC | 15V | - | - | - | - | - | 16.7 A | - | - | - | - | - | 251W (401W Forced Air) | Medical | 4 kV | 92% | -30°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 6.30" L x 3.39" W x 1.69" H (160.0mm x 86.1mm x 42.9mm) | CB, CE, cURus, TUV | - |
|
|
|
ULP275 (275W) |
Bulk |
Active | Open Frame | 1 | 80 ~ 264 VAC, 390VDC | 24V | - | - | - | - | - | 6.67 A | - | - | - | - | - | 160W (275W Forced Air) | ITE (Commercial) | 3 kV | 90% | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Standby Output, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 0.75" H (127.0mm x 76.2mm x 19.1mm) | CB, CE, cUL, NEMKO, UL | - |
|
|
|
ULP275 (275W) |
Bulk |
Active | Open Frame | 1 | 80 ~ 264 VAC, 390VDC | 12V | - | - | - | - | - | 13.33 A | - | - | - | - | - | 160W (275W Forced Air) | ITE (Commercial) | 3 kV | 88% | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Standby Output, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 0.75" H (127.0mm x 76.2mm x 19.1mm) | CB, CE, cUL, NEMKO, UL | - |
|
|
|
VMS-130-CNF (130W) |
Box |
Active | Enclosed | 1 | 90 ~ 264 VAC | 12V | - | - | - | - | - | 16.67 A | - | - | - | - | - | 200W | Medical | 4 kV | 92% | -20°C ~ 80°C (With Derating) | Universal Input | Chassis Mount | 4.61" L x 2.44" W x 1.58" H (117.0mm x 62.0mm x 40.0mm) | CB Scheme, EN, IEC, TUV, UL | 55011 Class B; 60601-1; 61000-3-2; 61000-3-3 |
|
|
|
CFM300M (300W) |
Box |
Active | Open Frame | 1 | 90 ~ 264 VAC | 36V | - | - | - | - | - | 8.34 A | - | - | - | - | - | 300W | Medical | 4 kV | 93.5% | -40°C ~ 80°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.42" H (127.0mm x 76.2mm x 36.1mm) | CE, cURus, FCC, TUV | - |
|
|
|
PQC250 (250W) |
Box |
Active | Open Frame | 1 | 90 ~ 264 VAC | 36V | - | - | - | - | - | 6.9 A | - | - | - | - | - | 248W | ITE (Commercial), Medical | 4 kV | 95% | -10°C ~ 70°C (With Derating) | Load Sharing, PFC, Remote Sense, Standby Output, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.38" H (127.0mm x 76.2mm x 35.1mm) | CB, CCC, cCSAus, CE, TUV | - |
|
|
|
PQC250 (250W) |
Box |
Active | Open Frame | 1 | 90 ~ 264 VAC | 54V | - | - | - | - | - | 4.6 A | - | - | - | - | - | 248W | ITE (Commercial), Medical | 4 kV | 95% | -10°C ~ 70°C (With Derating) | Load Sharing, PFC, Remote Sense, Standby Output, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.38" H (127.0mm x 76.2mm x 35.1mm) | CB, CCC, cCSAus, CE, TUV | - |
|
|
|
MULP275 (275W) |
Bulk |
Active | Open Frame | 1 | 80 ~ 264 VAC, 390VDC | 15V | - | - | - | - | - | 10.66 A | - | - | - | - | - | 160W (275W Forced Air) | Medical | 4 kV | 88% | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Standby Output, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 0.75" H (127.0mm x 76.2mm x 19.1mm) | CB, CE, cUL, NEMKO, UL | - |
|
|
|
MULP275 (275W) |
Bulk |
Active | Open Frame | 1 | 80 ~ 264 VAC, 390VDC | 48V | - | - | - | - | - | 3.33 A | - | - | - | - | - | 160W (275W Forced Air) | Medical | 4 kV | 92% | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Standby Output, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 0.75" H (127.0mm x 76.2mm x 19.1mm) | CB, CE, cUL, NEMKO, UL | - |