PDF |
Производитель, номер детали |
запрос цен |
Ряд |
Упаковка |
Product Status | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 | Power (Watts) | Applications | Voltage - Isolation | Efficiency | Operating Temperature | Features | Mounting Type | Size / Dimension | Approval Agency | Standard Number |
|
|
|
RPS-160 (160W) |
Box |
Active | Open Frame | 1 | 90 ~ 264 VAC, 127 ~ 370 VDC | 15V | - | - | - | - | - | 7.3 A | - | - | - | - | - | 110W (155W Forced Air) | Household Appliances, Medical | 4 kV | 87% | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.36" H (127.0mm x 76.2mm x 34.6mm) | CB, CE, cURus, TUV | - |
|
|
|
RSP-320 (320W) |
Box |
Active | Enclosed | 1 | 88 ~ 264 VAC, 124 ~ 370 VDC | 48V | - | - | - | - | - | 6.7 A | - | - | - | - | - | 322W | ITE (Commercial) | 3 kV | 90% | -30°C ~ 70°C (With Derating) | Adjustable Output, PFC, Universal Input | Chassis Mount | 8.46" L x 4.53" W x 1.18" H (215.0mm x 115.0mm x 30.0mm) | CB, CCC, CE, cURus, TUV | - |
|
|
|
ASM201 (200W) |
Box |
Active | Enclosed | 1 | 80 ~ 240 VAC | 12V | - | - | - | - | - | 11.7 A | - | - | - | - | - | 140W (200W Forced Air) | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C (With Derating) | Standby Output, Universal Input | Chassis Mount | 4.17" L x 2.68" W x 1.57" H (105.9mm x 68.1mm x 39.9mm) | CB, CE, cTUVus, TUV | 60601-1; 60950-1; 62368-1 |
|
|
|
ASM201 (200W) |
Box |
Active | Enclosed | 1 | 80 ~ 240 VAC | 15V | - | - | - | - | - | 9.4 A | - | - | - | - | - | 141W (201W Forced Air) | ITE (Commercial), Medical | 4 kV | 93% | -40°C ~ 85°C (With Derating) | Standby Output, Universal Input | Chassis Mount | 4.17" L x 2.68" W x 1.57" H (105.9mm x 68.1mm x 39.9mm) | CB, CE, cTUVus, TUV | 60601-1; 60950-1; 62368-1 |
|
|
|
ASM201 (200W) |
Box |
Active | Enclosed | 1 | 80 ~ 240 VAC | 24V | - | - | - | - | - | 5.9 A | - | - | - | - | - | 142W (202W Forced Air) | ITE (Commercial), Medical | 4 kV | 94% | -40°C ~ 85°C (With Derating) | Standby Output, Universal Input | Chassis Mount | 4.17" L x 2.68" W x 1.57" H (105.9mm x 68.1mm x 39.9mm) | CB, CE, cTUVus, TUV | 60601-1; 60950-1; 62368-1 |
|
|
|
SRP-40A (40W) |
Box |
Active | Open Frame | 3 | 100 ~ 240 VAC | 5V | 12V | -12V | - | - | - | 5 A | 2 A | 700 mA | - | - | - | 40W | Industrial, ITE (Commercial), Medical | - | 73% | 0°C ~ 70°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 4.25" L x 2.50" W x 1.20" H (107.9mm x 63.5mm x 30.5mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-45 (45W) |
Box |
Active | Open Frame | 3 | 85 ~ 264 VAC | 5V | 15V | -15V | - | - | - | 5 A | 1 A | 1 A | - | - | - | 45W | ITE (Commercial), Medical | - | 85% | 0°C ~ 70°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 4.25" L x 2.50" W x 0.83" H (108.0mm x 63.5mm x 21.1mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-45 (45W) |
Box |
Active | Open Frame | 3 | 85 ~ 264 VAC | 5V | 12V | -12V | - | - | - | 5 A | 1 A | 1 A | - | - | - | 45W | ITE (Commercial), Medical | - | 85% | 0°C ~ 70°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 4.25" L x 2.50" W x 0.83" H (108.0mm x 63.5mm x 21.1mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-45 (45W) |
Box |
Active | Open Frame | 2 | 85 ~ 264 VAC | 15V | -15V | - | - | - | - | 2 A | 2 A | - | - | - | - | 45W | ITE (Commercial), Medical | - | 85% | 0°C ~ 70°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 4.25" L x 2.50" W x 0.83" H (108.0mm x 63.5mm x 21.1mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-45 (45W) |
Box |
Active | Open Frame | 2 | 85 ~ 264 VAC | 5V | 12V | - | - | - | - | 5 A | 2 A | - | - | - | - | 45W | ITE (Commercial), Medical | - | 85% | 0°C ~ 70°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 4.25" L x 2.50" W x 0.83" H (108.0mm x 63.5mm x 21.1mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-45 (45W) |
Box |
Active | Open Frame | 2 | 85 ~ 264 VAC | 5V | 24V | - | - | - | - | 5 A | 1 A | - | - | - | - | 45W | ITE (Commercial), Medical | - | 85% | 0°C ~ 70°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 4.25" L x 2.50" W x 0.83" H (108.0mm x 63.5mm x 21.1mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-45 (45W) |
Box |
Active | Chassis | 2 | 85 ~ 264 VAC | 5V | 24V | - | - | - | - | 5 A | 1 A | - | - | - | - | 45W | ITE (Commercial), Medical | - | 85% | 0°C ~ 70°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 4.50" L x 2.75" W x 1.28" H (114.3mm x 69.9mm x 32.5mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-45 (45W) |
Box |
Active | Chassis | 2 | 85 ~ 264 VAC | 15V | -15V | - | - | - | - | 2 A | 2 A | - | - | - | - | 45W | ITE (Commercial), Medical | - | 85% | 0°C ~ 70°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 4.50" L x 2.75" W x 1.28" H (114.3mm x 69.9mm x 32.5mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-45 (45W) |
Box |
Active | Chassis | 2 | 85 ~ 264 VAC | 5V | 12V | - | - | - | - | 5 A | 2 A | - | - | - | - | 45W | ITE (Commercial), Medical | - | 85% | 0°C ~ 70°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 4.50" L x 2.75" W x 1.28" H (114.3mm x 69.9mm x 32.5mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-45 (45W) |
Box |
Active | Chassis | 2 | 85 ~ 264 VAC | 12V | -12V | - | - | - | - | 2 A | 2 A | - | - | - | - | 45W | ITE (Commercial), Medical | - | 85% | 0°C ~ 70°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 4.50" L x 2.75" W x 1.28" H (114.3mm x 69.9mm x 32.5mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-60 (60W) |
Box |
Active | Chassis | 1 | 85 ~ 264 VAC | 3.3V | - | - | - | - | - | 9 A | - | - | - | - | - | 30W | ITE (Commercial), Medical | - | 80% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 3.20" L x 2.43" W x 1.28" H (81.3mm x 61.7mm x 32.5mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-60 (60W) |
Box |
Active | Chassis | 1 | 85 ~ 264 VAC | 48V | - | - | - | - | - | 1.3 A | - | - | - | - | - | 60W | ITE (Commercial), Medical | - | 87% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 3.20" L x 2.43" W x 1.28" H (81.3mm x 61.7mm x 32.5mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-60 (60W) |
Box |
Active | Chassis | 1 | 85 ~ 264 VAC | 24V | - | - | - | - | - | 2.5 A | - | - | - | - | - | 60W | ITE (Commercial), Medical | - | 87% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 3.20" L x 2.43" W x 1.28" H (81.3mm x 61.7mm x 32.5mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-60 (60W) |
Box |
Active | Chassis | 1 | 85 ~ 264 VAC | 19V | - | - | - | - | - | 3.1 A | - | - | - | - | - | 60W | ITE (Commercial), Medical | - | 87% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 3.20" L x 2.43" W x 1.28" H (81.3mm x 61.7mm x 32.5mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-60 (60W) |
Box |
Active | Chassis | 1 | 85 ~ 264 VAC | 5V | - | - | - | - | - | 9 A | - | - | - | - | - | 45W | ITE (Commercial), Medical | - | 85% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 3.20" L x 2.43" W x 1.28" H (81.3mm x 61.7mm x 32.5mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |