PDF |
Производитель, номер детали |
запрос цен |
Ряд |
Упаковка |
Product Status | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 | Power (Watts) | Applications | Voltage - Isolation | Efficiency | Operating Temperature | Features | Mounting Type | Size / Dimension | Approval Agency | Standard Number |
|
|
|
GRN-80 (80W) |
Box |
Active | Chassis | 1 | 85 ~ 264 VAC | 3.3V | - | - | - | - | - | 16 A | - | - | - | - | - | 53W | ITE (Commercial), Medical | - | 82% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 4.50" L x 2.75" W x 1.28" H (114.3mm x 69.9mm x 32.5mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
MPC (250W) |
Box |
Active | ATX | 5 | 90 ~ 264 VAC | 3.3V | 5V | 12V | -5V | -12V | -12V | 9 A | 12 A | 14 A | 300 mA | 300 mA | - | 263W | ITE (Commercial), Medical | - | 85% | 0°C ~ 50°C (With Derating) | PFC, Standby Output, Universal Input | Chassis Mount | 7.48" L x 3.23" W x 1.61" H (190.0mm x 82.0mm x 41.0mm) | CE, cURus, FCC, TUV, VCCI | 60601-1; 60950-1 |
|
|
|
HEP-150 (150W) |
Box |
Active | Enclosed | 1 | 90 ~ 305 VAC, 127 ~ 431 VDC | 48V | - | - | - | - | - | 3.2 A | - | - | - | - | - | 154W | ITE (Commercial) | 3.75 kV | 94% | -55°C ~ 70°C (With Derating) | Adjustable Output, IP65, PFC | Chassis Mount | 8.98" L x 2.68" W x 1.53" H (228.0mm x 68.0mm x 38.8mm) | CB, CE, cURus | - |
|
|
|
VMS-225 (225W) |
Box |
Active | Open Frame | 1 | 80 ~ 264 VAC | 12V | - | - | - | - | - | 10 A | - | - | - | - | - | 120W (225W Forced Air) | Medical | 4.2 kV | 92% | -40°C ~ 70°C (With Derating) | Adjustable Output, Standby Output, Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.00" H (101.6mm x 50.8mm x 25.4mm) | CB Scheme, EN, FCC, IEC, TUV, UL | 55011 Class B; 60601-1; 61000-3-2; 61000-3-3 |
|
|
|
ECP (150W) |
Box |
Active | Open Frame | 1 | 85 ~ 264 VAC | 15V | - | - | - | - | - | 6.67 A | - | - | - | - | - | 100W (150W Forced Air) | ITE (Commercial), Medical | 4 kV | 91% | -20°C ~ 70°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.26" H (101.6mm x 50.8mm x 32.0mm) | CB, CE, TUV, UL | 62368-1 |
|
|
|
GRN-80 (80W) |
Box |
Active | Open Frame | 2 | 85 ~ 264 VAC | 5V | 12V | - | - | - | - | 8 A | 4 A | - | - | - | - | 80W | ITE (Commercial), Medical | - | 88% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.00" H (127.0mm x 76.2mm x 25.4mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-45 (45W) |
Box |
Active | Enclosed | 4 | 85 ~ 264 VAC | 5V | 24V | 12V | -12V | - | - | 5 A | 1 A | 1 A | 1 A | - | - | 45W | ITE (Commercial), Medical | - | 85% | 0°C ~ 70°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 4.50" L x 2.75" W x 1.28" H (114.3mm x 69.9mm x 32.5mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-45 (45W) |
Box |
Active | Enclosed | 4 | 85 ~ 264 VAC | 5V | 24V | 15V | -15V | - | - | 5 A | 1 A | 1 A | 1 A | - | - | 45W | ITE (Commercial), Medical | - | 85% | 0°C ~ 70°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 4.50" L x 2.75" W x 1.28" H (114.3mm x 69.9mm x 32.5mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-45 (45W) |
Box |
Active | Enclosed | 4 | 85 ~ 264 VAC | 3.3V | 5V | 12V | -12V | - | - | 5 A | 5 A | 1 A | 1 A | - | - | 45W | ITE (Commercial), Medical | - | 85% | 0°C ~ 70°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 4.50" L x 2.75" W x 1.28" H (114.3mm x 69.9mm x 32.5mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-45 (45W) |
Box |
Active | Enclosed | 4 | 85 ~ 264 VAC | 5V | -5V | 12V | -12V | - | - | 5 A | 5 A | 1 A | 1 A | - | - | 45W | ITE (Commercial), Medical | - | 85% | 0°C ~ 70°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 4.50" L x 2.75" W x 1.28" H (114.3mm x 69.9mm x 32.5mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-110 (110W) |
Box |
Active | Enclosed | 1 | 85 ~ 264 VAC | 5V | - | - | - | - | - | 22 A | - | - | - | - | - | 110W | ITE (Commercial), Medical | - | 86% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 5.25" L x 3.25" W x 1.50" H (133.4mm x 82.6mm x 38.1mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-110 (110W) |
Box |
Active | Enclosed | 1 | 85 ~ 264 VAC | 24V | - | - | - | - | - | 4.6 A | - | - | - | - | - | 110W | ITE (Commercial), Medical | - | 87% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 5.25" L x 3.25" W x 1.50" H (133.4mm x 82.6mm x 38.1mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-110 (110W) |
Box |
Active | Enclosed | 1 | 85 ~ 264 VAC | 3.3V | - | - | - | - | - | 22 A | - | - | - | - | - | 73W | ITE (Commercial), Medical | - | 82% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 5.25" L x 3.25" W x 1.50" H (133.4mm x 82.6mm x 38.1mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-110 (110W) |
Box |
Active | Enclosed | 1 | 85 ~ 264 VAC | 15V | - | - | - | - | - | 7.3 A | - | - | - | - | - | 110W | ITE (Commercial), Medical | - | 87% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 5.25" L x 3.25" W x 1.50" H (133.4mm x 82.6mm x 38.1mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-110 (110W) |
Box |
Active | Enclosed | 1 | 85 ~ 264 VAC | 12V | - | - | - | - | - | 9.2 A | - | - | - | - | - | 110W | ITE (Commercial), Medical | - | 87% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 5.25" L x 3.25" W x 1.50" H (133.4mm x 82.6mm x 38.1mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-110 (110W) |
Box |
Active | Enclosed | 1 | 85 ~ 264 VAC | 48V | - | - | - | - | - | 2.3 A | - | - | - | - | - | 110W | ITE (Commercial), Medical | - | 87% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 5.25" L x 3.25" W x 1.50" H (133.4mm x 82.6mm x 38.1mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-110 (110W) |
Box |
Active | Enclosed | 1 | 85 ~ 264 VAC | 28V | - | - | - | - | - | 3.9 A | - | - | - | - | - | 110W | ITE (Commercial), Medical | - | 87% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 5.25" L x 3.25" W x 1.50" H (133.4mm x 82.6mm x 38.1mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-80 (80W) |
Box |
Active | Enclosed | 1 | 85 ~ 264 VAC | 48V | - | - | - | - | - | 1.7 A | - | - | - | - | - | 80W | ITE (Commercial), Medical | - | 87% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 4.50" L x 2.75" W x 1.28" H (114.3mm x 69.9mm x 32.5mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-80 (80W) |
Box |
Active | Enclosed | 1 | 85 ~ 264 VAC | 3.3V | - | - | - | - | - | 16 A | - | - | - | - | - | 53W | ITE (Commercial), Medical | - | 82% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 4.50" L x 2.75" W x 1.28" H (114.3mm x 69.9mm x 32.5mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |
|
|
|
GRN-80 (80W) |
Box |
Active | Enclosed | 1 | 85 ~ 264 VAC | 5V | - | - | - | - | - | 16 A | - | - | - | - | - | 80W | ITE (Commercial), Medical | - | 85% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 4.50" L x 2.75" W x 1.28" H (114.3mm x 69.9mm x 32.5mm) | CE, cURus, TUV, UKCA | 60601-1; 62368-1 |