PDF |
Производитель, номер детали |
запрос цен |
Ряд |
Упаковка |
Product Status | Region Utilized | Form | Input Type | Voltage - Input | Voltage - Output | Current - Output (Max) | Power (Watts) | No Load Power Consumption | Polarization | Applications | Efficiency | Operating Temperature | Output Connector | Cord Length | Input Connector | Features | Size / Dimension | Approval Agency | Standard Number |
|
|
|
SDI50-U (50W) |
Box |
Active | International | Desktop (Class I) | Cord (Sold Separately) | 90 ~ 264 VAC | 18V | 2.78A | 50 W | 150mW (Max) | Positive Center | ITE (Commercial) | Level VI, CoC Tier 2 | 0°C ~ 40°C | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | 72" (1.83m) | IEC 320-C14 | - | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 |
|
|
|
KTPS50 (50W) |
Box |
Active | International | Desktop (Class I) | Cord (Sold Separately) | 100 ~ 240 VAC | 15V | 3.34A | 50 W | - | Positive Center | ITE (Commercial) | Level VI | 0°C ~ 40°C | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C14 | - | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | IEC | 60950-1 |
|
|
|
KTPS45 (45W) |
Box |
Active | International | Desktop (Class I) | Cord (Sold Separately) | 100 ~ 240 VAC | 9V | 5A | 45 W | - | Positive Center | ITE (Commercial) | Level VI | 0°C ~ 40°C | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C14 | - | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | IEC | 60950-1 |
|
|
|
TR70M (70W) |
Box |
Active | International | Desktop (Class II) | Cord (Sold Separately) | 80 ~ 264 VAC | 12V | 5.8A | 70 W | 150mW (Max) | Positive Center | Medical | Level VI, CoC Tier 2 | -20°C ~ 70°C | Barrel Plug R/A, 2.1mm I.D. x 5.5mm O.D. x 12.0mm | 48" (1.22m) | IEC 320-C8 | - | 4.72" L x 2.05" W x 1.22" H (120.0mm x 52.0mm x 31.0mm) | CE, cURus, FCC, Nemko | - |
|
|
|
QAWA-36 (36W) |
Bulk |
Active | North America | Wall Mount (Class II) | Fixed Blade | 100 ~ 240 VAC | 12V | 3A | 36 W | 100mW (Max) | Positive Center | ITE (Commercial) | Level VI | 0°C ~ 40°C | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 11.0mm | 59" (1.50m) | NEMA 1-15P | - | 3.11" L x 1.34" W x 2.91" H (79.0mm x 34.0mm x 74.0mm) | BSMI, CB, CCC, CE, cULus, FCC, GS, PSE, RCM | - |
|
|
|
QADA-65 (65W) |
Bulk |
Active | International | Desktop (Class I) | Cord (Sold Separately) | 100 ~ 240 VAC | 15V | 4.34A | 65 W | 210mW (Max) | Positive Center | - | Level VI | 0°C ~ 40°C | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 11.0mm | 59" (1.50m) | IEC 320-C14 | - | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | BSMI, CB, CCC, CE, cULus, FCC, GS, PSE | - |
|
|
|
TE30 (30W) |
Box |
Active | North America | Wall Mount (Class II) | Fixed Blade, Multi-Blade (Sold Separately) | 90 ~ 264 VAC | 5V | 4A | 20 W | 100mW (Max) | Positive Center | ITE (Commercial) | Level VI | -20°C ~ 40°C | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | 4.7' (1.45m) | NEMA 1-15P, Multi-Blade (Sold Separately) | - | 3.78" L x 2.17" W x 1.32" H (96.0mm x 55.0mm x 33.6mm) | CB, CE, DEMKO, UL | - |
|
|
|
GST60A (60W) |
Box |
Active | International | Desktop (Class I) | Cord (Sold Separately) | 90 ~ 264 VAC | 12V | 5A | 60 W | 75mW (Max) | Positive Center | ITE (Commercial) | Level VI | -30°C ~ 70°C | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 11.0mm | 39.4" (1.00m) | IEC 320-C14 | - | 4.92" L x 1.97" W x 1.24" H (125.0mm x 50.0mm x 31.5mm) | BIS, BSMI, CB, CCC, CE, cULus, EAC, GS, KC, PSE, RCM, SIRIM | - |
|
|
|
GSM40A (40W) |
Box |
Active | International | Desktop (Class I) | Cord (Sold Separately) | 80 ~ 264 VAC | 12V | 3.34A | 40 W | 100mW (Max) | Positive Center | Medical | Level VI | -30°C ~ 70°C | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 11.0mm | 39.4" (1.00m) | IEC 320-C14 | - | 4.92" L x 1.97" W x 1.24" H (125.0mm x 50.0mm x 31.5mm) | CB, CE, cURus, TUV | - |
|
|
|
ME30 (30W) |
Box |
Active | International | Desktop (Class I) | Cord (Sold Separately) | 90 ~ 264 VAC | 24V | 1.33A | 32 W | 100mW (Max) | Positive Center | Medical | Level VI | -20°C ~ 50°C | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | 4.7' (1.45m) | IEC 320-C14 | - | 3.76" L x 2.13" W x 1.22" H (95.5mm x 54.0mm x 31.0mm) | CE | - |
|
|
|
IPD50 (50W) |
Box |
Active | North America | Desktop (Class I) | Cord (Sold Separately) | 85 ~ 264 VAC | 12V | 4.25A | 51 W | 100mW (Max) | Positive Center | ITE (Commercial) | Level VI | 0°C ~ 60°C | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | 48" (1.22m) | IEC 320-C14 | - | 4.50" L x 2.26" W x 1.44" H (114.2mm x 57.5mm x 36.5mm) | CE, cTUVus | - |
|
|
|
SMI36 (36W) |
Box |
Active | International | Wall Mount (Class II) | Multi-Blade (Included) | 90 ~ 264 VAC | 5V | 5A | 25 W | 100mW (Max) | Positive Center | ITE (Commercial) | Level VI, CoC Tier 2 | 0°C ~ 40°C | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | 39.4" (1.00m) | Multi-Blade | - | 3.10" L x 1.34" W x 2.60" H (78.5mm x 34.0mm x 66.0mm) | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, UL | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 |
|
|
|
SMI36 (36W) |
Box |
Active | International | Wall Mount (Class II) | Multi-Blade (Included) | 90 ~ 264 VAC | 5V | 5A | 25 W | 100mW (Max) | Positive Center | ITE (Commercial) | Level VI, CoC Tier 2 | 0°C ~ 40°C | Barrel Plug R/A, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | 39.4" (1.00m) | Multi-Blade | - | 3.10" L x 1.34" W x 2.60" H (78.5mm x 34.0mm x 66.0mm) | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, UL | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 |
|
|
|
SMI36 (36W) |
Box |
Active | International | Wall Mount (Class II) | Multi-Blade (Included) | 90 ~ 264 VAC | 9V | 3.34A | 30 W | 100mW (Max) | Positive Center | ITE (Commercial) | Level VI, CoC Tier 2 | 0°C ~ 40°C | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | Multi-Blade | - | 3.10" L x 1.34" W x 2.60" H (78.5mm x 34.0mm x 66.0mm) | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, UL | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 |
|
|
|
SGA40U (40W) |
Box |
Active | North America | Wall Mount (Class II) | Fixed Blade | 90 ~ 264 VAC | 12V | 3.33A | 40 W | 75mW (Max) | Positive Center | ITE (Commercial) | Level VI | -20°C ~ 50°C | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 11.0mm | 39.4" (1.00m) | NEMA 1-15P | - | 2.97" L x 1.26" W x 1.87" H (75.5mm x 32.0mm x 47.5mm) | CB, cULus | - |
|
|
|
Tri-Mag®, L6R60D (65W) |
Box |
Active | International | Desktop (Class I) | Cord (Sold Separately) | 90 ~ 264 VAC | 12V | 5.41A | 65 W | 100mW (Max) | - | ITE (Commercial) | Level VI | 0°C ~ 40°C | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | 39.4" (1.00m) | IEC 320-C14 | - | 4.72" L x 2.01" W x 1.34" H (120.0mm x 51.0mm x 34.0mm) | cUL, FCC, UL | 62368-1 |
|
|
|
KTPS65 (65W) |
Box |
Active | International | Desktop (Class I) | Cord (Sold Separately) | 100 ~ 240 VAC | 12V | 5A | 65 W | - | Positive Center | ITE (Commercial) | Level VI | 0°C ~ 40°C | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C14 | - | 4.53" L x 2.09" W x 1.50" H (115.0mm x 53.0mm x 38.0mm) | IEC | 60950-1 |
|
|
|
GSM60B (60W) |
Box |
Active | International | Desktop (Class II) | Cord (Sold Separately) | 80 ~ 264 VAC | 12V | 5A | 60 W | 100mW (Max) | Positive Center | Medical | Level VI | -30°C ~ 70°C | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 11.0mm | 39.4" (1.00m) | IEC 320-C8 | - | 4.92" L x 1.97" W x 1.24" H (125.0mm x 50.0mm x 31.5mm) | CB, CE, cRUus, TUV | - |
|
|
|
GSM60A (60W) |
Box |
Active | International | Desktop (Class I) | Cord (Sold Separately) | 80 ~ 264 VAC | 12V | 5A | 60 W | 100mW (Max) | Positive Center | Medical | Level VI | -30°C ~ 70°C | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 11.0mm | 39.4" (1.00m) | IEC 320-C14 | - | 4.92" L x 1.97" W x 1.24" H (125.0mm x 50.0mm x 31.5mm) | CB, CE, cRUus, TUV | - |
|
|
|
GSM60A (60W) |
Box |
Active | International | Desktop (Class I) | Cord (Sold Separately) | 80 ~ 264 VAC | 24V | 2.5A | 60 W | 100mW (Max) | Positive Center | Medical | Level VI | -30°C ~ 70°C | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 11.0mm | 59" (1.50m) | IEC 320-C14 | - | 4.92" L x 1.97" W x 1.24" H (125.0mm x 50.0mm x 31.5mm) | CB, CE, cRUus, TUV | - |