Protection Relays & Systems
1363 Предметы
PDF Производитель, номер детали запрос цен Ряд Упаковка Product StatusFunctionVoltage - SupplyTrip RangeDelay TimeMounting TypeTermination StyleFeaturesOperating Temperature
1-1618060-3
1-1618060-3
1100DC-11X=WILMAR CURRENT RELA
TE Connectivity Aerospace, Defense and Marine
Bulk Active--------
4-1618103-1
4-1618103-1
WCB-120AC-2=WILMAR CURRENT BAL
TE Connectivity Aerospace, Defense and Marine
Bulk Active--------
PGR-6100-120
PGR-6100-120
MOTOR GROUND FAULT & INSUL RELAY
Littelfuse Inc.
PGR-6100 Bulk ActiveGround Fault120VAC10mA ~ 3A0.05 ~ 1sChassis Mount, DIN RailScrew TerminalHarmonic Filtering, Manual Reset, Test Button-
6-1618082-4
6-1618082-4
401-43SX=RELAY, UNDERVOLTAGE
TE Connectivity Aerospace, Defense and Marine
Bulk Active--------
1350X
1350X
1350X=WILMAR CURRENT
TE Connectivity Aerospace, Defense and Marine
Bulk Active--------
1-1618060-7
1-1618060-7
1100DC-22SX=WILMAR CURRENT REL
TE Connectivity Aerospace, Defense and Marine
Bulk Active--------
SE-325DN
SE-325DN
NGR MONITOR 120 VAC/VDC NON-LATC
Littelfuse Inc.
SE-325 Bulk ActiveGround Fault, Overvoltage120VAC/DC0.5 ~ 4A0.1 ~ 2sChassis MountScrew TerminalManual Reset-40°C ~ 60°C
SE-325DS
SE-325DS
NGR MONITOR 120 VAC/VDC EXT RF T
Littelfuse Inc.
SE-325 Bulk ActiveGround Fault, Overvoltage120VAC/DC0.5 ~ 4A0.1 ~ 2sChassis MountScrew TerminalManual Reset-40°C ~ 60°C
SE-325DT
SE-325DT
NGR MON 120V GF TIME 0.1 TO 5 S
Littelfuse Inc.
SE-325 Bulk ActiveGround Fault, Overvoltage120VAC/DC0.5 ~ 4A0.1 ~ 2sChassis MountScrew TerminalManual Reset-40°C ~ 60°C
SE-325ESNT
SE-325ESNT
NGR MON 240 VAC EXT RF NL GF 0.1
Littelfuse Inc.
SE-325 Bulk ActiveGround Fault, Overvoltage240VAC0.5 ~ 4A0.1 ~ 2sChassis MountScrew TerminalManual Reset-40°C ~ 60°C
SE-325SNT
SE-325SNT
NGR MON 120 VAC EXT RF GF TIME 0
Littelfuse Inc.
SE-325 Bulk ActiveGround Fault, Overvoltage120VAC0.5 ~ 4A0.1 ~ 2sChassis MountScrew TerminalManual Reset-40°C ~ 60°C
1-1618068-3
1-1618068-3
21-853=WILMAR LATCHING RELAY
TE Connectivity Aerospace, Defense and Marine
Bulk Active--------
1-1618062-0
1-1618062-0
1351-1X=WILMAR DIFFERENTIAL RE
TE Connectivity Aerospace, Defense and Marine
Bulk Active--------
EL731-02-00
EL731-02-00
AC/DC EARTH-LKGE RELAY 75-275V
Littelfuse Inc.
EL731 Bulk ActiveGround Fault, Overtemperature120 ~ 240VAC/DC0.03 ~ 5A0.05 ~ 2sPanel MountScrew TerminalCT Loop Monitoring, Harmonic Filtering-40°C ~ 60°C
EL731-01-00
EL731-01-00
AC/DC EARTH-LKGE RELAY 75-275V
Littelfuse Inc.
EL731 Bulk ActiveGround Fault, Overtemperature120 ~ 240VAC/DC0.03 ~ 5A0.05 ~ 2sPanel MountScrew TerminalCT Loop Monitoring, Harmonic Filtering-40°C ~ 60°C
EL731-03-00
EL731-03-00
AC/DC EARTH-LKGE RELAY
Littelfuse Inc.
EL731 Bulk ActiveGround Fault, Overtemperature120 ~ 240VAC/DC0.03 ~ 5A0.05 ~ 2sPanel MountScrew TerminalCT Loop Monitoring, Harmonic Filtering-40°C ~ 60°C
EL731-04-00
EL731-04-00
AC/DC EARTH-LKGE RELAY
Littelfuse Inc.
EL731 Bulk ActiveGround Fault, Overtemperature120 ~ 240VAC/DC0.03 ~ 5A0.05 ~ 2sPanel MountScrew TerminalCT Loop Monitoring, Harmonic Filtering-40°C ~ 60°C
1618062-4
1618062-4
1300X=WILMAR PHASE BALANCE
TE Connectivity Aerospace, Defense and Marine
Bulk Active--------
1-1618103-3
1-1618103-3
WC1G-120AC=WILMAR GND FAULT DE
TE Connectivity Aerospace, Defense and Marine
WC1G Bulk ActiveGround Fault120VAC------
7-1618401-1
7-1618401-1
WC1G-120AC-01=RELAY, GROUND FAUL
TE Connectivity Aerospace, Defense and Marine
WC1G Bulk ActiveGround Fault120VAC------