PDF |
Производитель, номер детали |
запрос цен |
Ряд |
Упаковка |
Product Status | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 | Power (Watts) | Applications | Voltage - Isolation | Efficiency | Operating Temperature | Features | Mounting Type | Size / Dimension | Approval Agency | Standard Number |
|
|
|
Linear BAA |
Bulk |
Active | Linear | 3 | 100, 120, 220, 230, 240 VAC | 5V | 12V | -12V | - | - | - | 3 A | 1 A | 1 A | - | - | - | 39W | ITE (Commercial) | 4.242 kV | - | 0°C ~ 50°C | Adjustable Output, Remote Sense | Chassis Mount | 10.25" L x 4.00" W x 2.95" H (260.4mm x 101.6mm x 74.9mm) | CE, CSA, UL | 60950-1; 62368-1 |
|
|
|
VOF-350 (350W) |
Tray |
Active | Open Frame | 1 | 90 ~ 264 VAC | 24V | - | - | - | - | - | 8.33 A | - | - | - | - | - | 200W (350W Forced Air) | ITE (Commercial) | 3 kV | 93% | -40°C ~ 70°C (With Derating) | Adjustable Output, Standby Output, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.00" H (127.0mm x 76.2mm x 25.4mm) | CB Scheme, EN, FCC, IEC, SIQ, TUV, UL | 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3 |
|
|
|
GPM40 (40W) |
Box |
Active | Open Frame | 3 | 85 ~ 264 VAC | 5.1V | 12V | -12V | - | - | - | 4 A | 2 A | 400 mA | - | - | - | 40W (50W Forced Air) | Medical | - | 70% | 0°C ~ 50°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.28" H (127.0mm x 76.2mm x 32.5mm) | CE, cURus, TUV | - |
|
|
|
GLC65 (65W) |
Bulk |
Not For New Designs | Open Frame | 3 | 90 ~ 264 VAC | 5V | 12V | -12V | - | - | - | 7 A | 3 A | 2.5 A | - | - | - | 65W | ITE (Commercial) | - | 80% | 0°C ~ 50°C | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.25" H (127.0mm x 76.2mm x 31.8mm) | CE, cURus, TUV | - |
|
|
|
VF-S250 (250W) |
Box |
Active | Enclosed | 1 | 90 ~ 264 VAC | 24V | - | - | - | - | - | 10.42 A | - | - | - | - | - | 250W | ITE (Commercial) | 3 kV | 83% | 0°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Universal Input | Chassis Mount | 5.00" L x 3.20" W x 2.00" H (127.0mm x 81.3mm x 50.8mm) | CB Scheme, EN, IEC, SIQ, TUV, UL | 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 |
|
|
|
VF-S320 (320W) |
Tray |
Active | Open Frame | 1 | 90 ~ 132 VAC, 180 ~ 264 VAC | 24V | - | - | - | - | - | 7.5 A | - | - | - | - | - | 180W (320W Forced Air) | ITE (Commercial) | 3 kV | 83% | 0°C ~ 70°C (With Derating) | Adjustable Output, PFC, Universal Input | Chassis Mount | 6.00" L x 4.00" W x 1.50" H (152.4mm x 101.6mm x 38.1mm) | CB Scheme, EN, IEC, SIQ, TUV, UL | 55024; 60950-1; 61000-3-2; 61000-3-3; 62368-1 |
|
|
|
Silver Line |
Bulk |
Not For New Designs | Open Frame | 3 | 100 ~ 240 VAC | 5V | 12V | -12V | - | - | - | 2 A | 4 A | 4 A | - | - | - | 106W | ITE (Commercial) | - | - | 0°C ~ 50°C | Adjustable Output, Remote Sense | Chassis Mount | 6.50" L x 4.00" W x 1.62" H (165.1mm x 101.6mm x 41.1mm) | CSA, cURus | - |
|
|
|
VF-D250-D (250W) |
Tray |
Obsolete | Enclosed | 2 | 90 ~ 264 VAC | 12V | 24V | - | - | - | - | 12 A | 6 A | - | - | - | - | 250W | ITE (Commercial) | 3 kV | 70% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote On/Off | Chassis Mount | 5.00" L x 3.20" W x 1.50" H (127.0mm x 81.3mm x 38.1mm) | CB Scheme, EN, IEC, SIQ, TUV, UL | 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 |
|
|
|
GLC65 (65W) |
Bulk |
Not For New Designs | Open Frame | 3 | 90 ~ 264 VAC | 5V | 24V | 12V | - | - | - | 7 A | 1.5 A | 2.5 A | - | - | - | 65W | ITE (Commercial) | - | 80% | 0°C ~ 50°C | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.25" H (127.0mm x 76.2mm x 31.8mm) | CE, cURus, TUV | - |
|
|
|
Linear BB |
Bulk |
Active | Linear | 2 | 100 ~ 240 VAC | 15V | -15V | - | - | - | - | 1.5 A | 1.5 A | - | - | - | - | 41W | ITE (Commercial) | - | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 7.00" L x 4.88" W x 2.50" H (177.8mm x 124.0mm x 63.5mm) | CE, cURus, TUV | - |
|
|
|
VCCS300S (300W) |
Box |
Active | Open Frame | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 24V | - | - | - | - | - | 12.5 A | - | - | - | - | - | 300W | ITE (Commercial) | 4 kV | 95% | -40°C ~ 70°C (With Derating) | PFC, Universal Input | Chassis Mount | 3.99" L x 2.13" W x 1.58" H (101.3mm x 54.0mm x 40.2mm) | CE | 62368-1 |
|
|
|
VCCS300S (300W) |
Box |
Active | Open Frame | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 12V | - | - | - | - | - | 25 A | - | - | - | - | - | 300W | ITE (Commercial) | 4 kV | 95% | -40°C ~ 70°C (With Derating) | PFC, Universal Input | Chassis Mount | 3.99" L x 2.13" W x 1.58" H (101.3mm x 54.0mm x 40.2mm) | CE | 62368-1 |
|
|
|
MPB125 (125W) |
Bulk |
Active | Open Frame | 4 | 90 ~ 264 VAC | 3.3V | 5V | 12V | -12V | - | - | 10 A | 15 A | 5 A | 500 mA | - | - | 125W | ITE (Commercial) | 3 kV | 83% | -20°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.00" H (127.0mm x 76.2mm x 25.4mm) | CE | - |
|
|
|
VCCS300M (300W) |
Box |
Active | Open Frame | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 24V | - | - | - | - | - | 12.5 A | - | - | - | - | - | 300W | Medical | 4 kV | 95% | -40°C ~ 70°C (With Derating) | PFC, Universal Input | Chassis Mount | 3.99" L x 2.13" W x 1.58" H (101.3mm x 54.0mm x 40.2mm) | CE | 60601-1 |
|
|
|
VCCS300M (300W) |
Box |
Active | Open Frame | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 12V | - | - | - | - | - | 25 A | - | - | - | - | - | 300W | Medical | 4 kV | 95% | -40°C ~ 70°C (With Derating) | PFC, Universal Input | Chassis Mount | 3.99" L x 2.13" W x 1.58" H (101.3mm x 54.0mm x 40.2mm) | CE | 60601-1 |
|
|
|
MAP40 (40W) |
Bulk |
Active | Open Frame | 3 | 90 ~ 264 VAC | 5V | 12V | -12V | - | - | - | 3 A | 2 A | 300 mA | - | - | - | 40W | ITE (Commercial) | 2.6 kV | 70% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.25" H (127.0mm x 76.2mm x 31.8mm) | CE | - |
|
|
|
MAP40 (40W) |
Bulk |
Active | Open Frame | 3 | 90 ~ 264 VAC | 5V | 15V | -15V | - | - | - | 3 A | 2 A | 200 mA | - | - | - | 40W | ITE (Commercial) | 2.6 kV | 70% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.25" H (127.0mm x 76.2mm x 31.8mm) | CE | - |
|
|
|
MAP40 (40W) |
Bulk |
Active | Open Frame | 3 | 90 ~ 264 VAC | 5V | 24V | -12V | - | - | - | 3 A | 1 A | 300 mA | - | - | - | 40W | ITE (Commercial) | 2.6 kV | 70% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.25" H (127.0mm x 76.2mm x 31.8mm) | CE | - |
|
|
|
IMA-400 (400W) |
Box |
Active | Open Frame | 1 | 80 ~ 275 VAC, 120 ~ 300 VDC | 24V | - | - | - | - | - | 16.7 A | - | - | - | - | - | 400W | ITE (Commercial), Medical | 4 kV | 94% | -20°C ~ 70°C (With Derating) | Adjustable Output, DC Input Capable, Load Sharing, PFC, PMBus™, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 6.96" L x 4.00" W x 1.60" H (176.8mm x 101.6mm x 40.6mm) | - | - |
|
|
|
VF-D320-D (300W) |
Box |
Active | Enclosed | 2 | 90 ~ 132 VAC, 180 ~ 264 VAC | 12V | 24V | - | - | - | - | 16.67 A | 8.33 A | - | - | - | - | 320W | ITE (Commercial) | 3 kV | 75% | 0°C ~ 70°C (With Derating) | Adjustable Output, PFC, Universal Input | Chassis Mount | 7.00" L x 4.00" W x 1.60" H (177.8mm x 101.6mm x 40.6mm) | CB Scheme, EN, IEC, SIQ, TUV, UL | 55024; 60950-1; 61000-3-2; 61000-3-3; 62368-1 |