PDF |
Производитель, номер детали |
запрос цен |
Ряд |
Упаковка |
Product Status | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 | Power (Watts) | Applications | Voltage - Isolation | Efficiency | Operating Temperature | Features | Mounting Type | Size / Dimension | Approval Agency | Standard Number |
|
|
|
Linear D |
Bulk |
Active | Linear | 3 | 100, 120, 220, 230, 240 VAC | 5V | 12V | -12V | - | - | - | 6 A | 1 A | 1 A | - | - | - | 54W | ITE (Commercial) | 4.242 kV | 45% | 0°C ~ 50°C | Adjustable Output, Remote Sense | Chassis Mount | 9.00" L x 4.87" W x 3.28" H (228.6mm x 123.7mm x 83.3mm) | CE, CSA, UL | 60950-1; 62368-1 |
|
|
|
Linear D |
Bulk |
Active | Linear | 1 | 100, 120, 220, 230, 240 VAC | 48V | - | - | - | - | - | 3 A | - | - | - | - | - | 144W | ITE (Commercial) | 4.242 kV | 60% | 0°C ~ 50°C | Adjustable Output, Remote Sense | Chassis Mount | 9.00" L x 4.87" W x 3.28" H (228.6mm x 123.7mm x 83.3mm) | CE, CSA, UL | 60950-1; 62368-1 |
|
|
|
CUS600M (600W) |
Box |
Active | Open Frame | 1 | 85 ~ 265 VAC | 19V | - | - | - | - | - | 21.1 A | - | - | - | - | - | 401W (600W Forced Air) | ITE (Commercial), Medical | 4 kV | 96% | -20°C ~ 70°C (With Derating) | Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.34" H (127.0mm x 76.2mm x 34.0mm) | CE | 60601-1; 60950-1; 62368-1 |
|
|
|
Linear CC |
Bulk |
Active | Linear | 2 | 100, 120, 220, 230, 240 VAC | 15V | -15V | - | - | - | - | 3.4 A | 3.4 A | - | - | - | - | 90W | ITE (Commercial) | 4.242 kV | 55% | 0°C ~ 50°C | Adjustable Output, Remote Sense | Chassis Mount | 9.38" L x 4.87" W x 3.28" H (238.3mm x 123.7mm x 83.3mm) | CE, CSA, UL | 60950-1; 62368-1 |
|
|
|
RWS-B (600W) |
Bulk |
Active | Enclosed | 1 | 85 ~ 265 VAC | 12V | - | - | - | - | - | 50 A | - | - | - | - | - | 600W | ITE (Commercial) | 3 kV | 84% | -20°C ~ 70°C (With Derating) | Adjustable Output, DC Input Capable, Universal Input | Chassis Mount | 7.48" L x 4.72" W x 2.40" H (190.0mm x 120.0mm x 61.0mm) | CE | - |
|
|
|
IMA-600 (600W) |
Box |
Active | Enclosed | 1 | 80 ~ 275 VAC, 120 ~ 300 VDC | 12V | - | - | - | - | - | 50 A | - | - | - | - | - | 600W | ITE (Commercial), Medical | 4 kV | 92% | -20°C ~ 70°C (With Derating) | Adjustable Output, DC Input Capable, Load Sharing, PFC, PMBus™, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 7.00" L x 4.00" W x 1.60" H (177.8mm x 101.6mm x 40.6mm) | - | - |
|
|
|
JWT (75W) |
Bulk |
Not For New Designs | Enclosed | 3 | 85 ~ 265 VAC | 5V | 12V | -12V | - | - | - | 8 A | 4 A | 500 mA | - | - | - | 75W | ITE (Commercial) | 3 kV | 72% | -10°C ~ 65°C (With Derating) | Adjustable Output, DC Input Capable, PFC, Universal Input | Chassis Mount | 7.40" L x 3.62" W x 1.65" H (188.0mm x 91.9mm x 41.9mm) | CE | - |
|
|
|
GPFM115 (115W) |
Box |
Not For New Designs | Open Frame | 1 | 85 ~ 264 VAC | 12V | - | - | - | - | - | 6.7 A | - | - | - | - | - | 80W (115W Forced Air) | Medical | - | 81% | 0°C ~ 50°C | Adjustable Output, PFC, Remote Sense, Universal Input | Chassis Mount | 5.25" L x 3.30" W x 1.50" H (133.4mm x 83.8mm x 38.1mm) | CE, cURus, TUV | - |
|
|
|
GPFM115 (115W) |
Box |
Not For New Designs | Open Frame | 1 | 85 ~ 264 VAC | 28V | - | - | - | - | - | 2.9 A | - | - | - | - | - | 80W (115W Forced Air) | Medical | - | 81% | 0°C ~ 50°C | Adjustable Output, PFC, Remote Sense, Universal Input | Chassis Mount | 5.25" L x 3.30" W x 1.50" H (133.4mm x 83.8mm x 38.1mm) | CE, cURus, TUV | - |
|
|
|
Linear E |
Bulk |
Active | Linear | 1 | 100 ~ 240 VAC | 24V | - | - | - | - | - | 7.2 A | - | - | - | - | - | 173W | ITE (Commercial) | - | 60% | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 14.00" L x 4.88" W x 2.75" H (335.6mm x 124.0mm x 69.8mm) | CE, cURus, TUV | - |
|
|
|
NGB660 (660W) |
Box |
Active | Open Frame | 1 | 80 ~ 264 VAC | 48V | - | - | - | - | - | 9.38 A | - | - | - | - | - | 450W (662W Forced Air) | ITE (Commercial), Medical | 4.5 kV | 90% | -20°C ~ 80°C (With Derating) | Adjustable Output, Standby Output, Universal Input | Chassis Mount | 6.00" L x 4.00" W x 1.55" H (152.4mm x 101.6mm x 39.4mm) | CE, CSA, cURus, UL | 60601-1; 62368-1 |
|
|
|
MAP55 (55W) |
Bulk |
Active | Open Frame | 4 | 90 ~ 264 VAC | 5V | 24V | -12V | 12V | - | - | 6 A | 1.5 A | 500 mA | 500 mA | - | - | 55W | ITE (Commercial) | 2.6 kV | 73% | 0°C ~ 70°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 6.00" L x 3.27" W x 1.60" H (152.4mm x 83.1mm x 40.6mm) | CE | - |
|
|
|
VOF-550 (550W) |
Box |
Active | Open Frame | 1 | 90 ~ 264 VAC | 24V | - | - | - | - | - | 6.25 A | - | - | - | - | - | 150W (550W Forced Air) | ITE (Commercial) | 3 kV | 91% | -40°C ~ 70°C (With Derating) | Adjustable Output, Standby Output, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.50" H (127.0mm x 76.2mm x 38.1mm) | CB Scheme, EN, FCC, IEC, SIQ, TUV, UL | 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3 |
|
|
|
MINT1400 (400W) |
Bulk |
Not For New Designs | Open Frame | 1 | 80 ~ 270 VAC | 24V | - | - | - | - | - | 10.4 A | - | - | - | - | - | 250W (400W Forced Air) | Medical | 4 kV | 88% | 0°C ~ 70°C (With Derating) | Remote On/Off, Remote Sense, Standby Output, Universal Output | Chassis Mount | 7.00" L x 3.94" W x 1.57" H (177.8mm x 100.0mm x 40.0mm) | CE, cURus | - |
|
|
|
D1U54P-W-650 (650W) |
Box |
Active | Front End | 1 | 90 ~ 264 VAC | 12V | - | - | - | - | - | 54.2 A | - | - | - | - | - | 650W | ITE (Commercial) | 3 kV | 94% | -40°C ~ 70°C | Hot Swappable, I²C™ Interface, Load Sharing, PFC, PMBus™, Remote On/Off, Remote Sense, Standby Output, Universal Input | Rack Mount | 9.00" L x 2.15" W x 1.57" H (228.6mm x 54.5mm x 40.0mm) | CB, cCSAus, CE, TUV | - |
|
|
|
CCL400 (400W) |
Box |
Active | Open Frame | 1 | 85 ~ 264 VAC | 12V | - | - | - | - | - | 33.3 A | - | - | - | - | - | 400W | ITE (Commercial), Medical | 4 kV | 94% | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 7.00" L x 3.95" W x 1.57" H (177.8mm x 100.3mm x 39.9mm) | CB, CE, TUV, UL | 62368-1 |
|
|
|
Linear DCC |
Bulk |
Active | Linear | 3 | 100, 120, 220, 230, 240 VAC | 5V | 12V | -12V | - | - | - | 12 A | 3.4 A | 3 A | - | - | - | 150W | ITE (Commercial) | 4.242 kV | 45% | 0°C ~ 50°C | Adjustable Output, Remote Sense | Chassis Mount | 15.00" L x 4.88" W x 4.55" H (381.0mm x 124.0mm x 115.6mm) | CE, CSA, UL | 60950-1; 62368-1 |
|
|
|
Linear F |
Bulk |
Active | Linear | 1 | 100, 120, 220, 230, 240 VAC | 24V | - | - | - | - | - | 12 A | - | - | - | - | - | 288W | ITE (Commercial) | 4.242 kV | 60% | 0°C ~ 50°C | Adjustable Output, Remote Sense | Chassis Mount | 16.75" L x 4.88" W x 5.00" H (425.5mm x 124.0mm x 127.0mm) | CE, CSA, UL | 60950-1; 62368-1 |
|
|
|
ADA (750W) |
Box |
Active | Enclosed | 1 | 85 ~ 264 VAC | 48V | - | - | - | - | - | 9 A | - | - | - | - | - | 432W (744W Forced Air) | ITE (Commercial) | 3 kV | 89% | -10°C ~ 71°C (With Derating) | Adjustable Output, DC Input Capable, PFC, Universal Input | Chassis Mount | 6.91" L x 5.00" W x 2.76" H (175.5mm x 127.0mm x 70.0mm) | CE, CSA, cURus, TUV, UL | 60950-1; 62368-1 |
|
|
|
LCM1500 (1500W) |
Bulk |
Active | Front End | 1 | 90 ~ 264 VAC | 24V | - | - | - | - | - | 67 A | - | - | - | - | - | 1500W | ITE (Commercial), Medical | 4 kV | 91% | -40°C ~ 70°C (With Derating) | Adjustable Output, I²C™ Interface, Load Sharing, PFC, PMBus™, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.00" L x 5.20" W x 2.43" H (254.0mm x 132.0mm x 61.7mm) | BSMI, CB, CCC, CE, cURus, TUV | - |